HughesNet Required! The symbol rate is enter in Msps (Mega Symbols
per Second). Again this value is only needed in HughesNet mode.
Example; 30,000,000 symbols per second is entered as 30 Msps.
LO Frequency (10750)
LO Frequency is used in the LNB to mix with the incoming RF signal to
produce a IF Frequency in the 950 to 2150 MHz range. Check with the
Modem supplier to see what IF Frequency is needed for your specific
application.
The Default LO Frequency is 10750 MHz. This value is usually set
between 9750 to 11300 MHz. It is extremely important this value is set
correctly for proper D3 operation.
22Khz Tone (Disabled)
The 22Khz Tone can be used to switch the LO Oscillator from one
frequency to another. Some Modems may require 22Khz tone for other
reasons. Check with your Modem Hardware supplier or ISP to see if
22Khz tone is necessary for your application.
Signal Trigger (9)
Signal Trigger is a numerical value that represents a change of Signal
Strength Level during a small time period. When this value is triggered
the D3 will initial a Signal Identification Peak.
The Signal Trigger Value is set to Default 9. It can be adjusted from 0 to
40. The lower this value can be set the wider view of the sky for a quicker
search. If this value is set too low the D3 will begin to stop on false
targets such as trees, lights, and buildings. The higher this value is set the
narrower the sky view search angle.
Isolation Optimization (Medium)
Isolation Optimization is used to set Cross Polarization (CrossPol) of the
antenna Transmitter to an acceptable Isolation level.
Low
When set to Low the skew CrossPol value is determined by calculating the
proper skew rotation of the RF Assembly using GPS. If Skew has ever
been set to Medium or High mode for initial CrossPol to Optimize the
Comentarios a estos manuales